CONVERTER CHARACTERISTICS
Transient power....................................................................................................... 20 kW
Starting power (for motors starting)........................................................................ 15 kW
Permanent rms power.............................................................................................. 8 kW
Frequency................................................................................................................ 50 or 60 Hz
Frequency maximum variation................................................................................. 0.1%
Output voltage (rms)................................................................................................ 110, 120, 220, 240 V
Output voltage maximum variation........................................................................... 5%
Reactive energy recovery....................................................................................... > 90%
Performance with resistive loads........................................................................... > 97%

ORT– F1– 8 CONVERTER DIMENSIONS
Length..................................................................................................................... 43 cm.
Width....................................................................................................................... 32 cm.
Height...................................................................................................................... 16 cm.
Weight..................................................................................................................... 12.3 kg.

Up

CONVERTER ORT-F1-16 (SINGLE PHASE)  

CONVERTER CHARACTERISTICS
Transient power....................................................................................................... 40 kW
Starting power (for motors starting)........................................................................ 30 kW
Permanent rms power.............................................................................................. 16 kW
Frequency................................................................................................................ 50 or 60 Hz
Frequency maximum variation................................................................................. 0.1%
Output voltage (rms)................................................................................................ 110, 120, 220, 240 V
Output voltage maximum variation........................................................................... 5%
Reactive energy recovery....................................................................................... > 90%
Performance with resistive loads........................................................................... > 97%

ORT– F1– 16 CONVERTER DIMENSIONS
Length..................................................................................................................... 58 cm.
Width....................................................................................................................... 46 cm.
Height...................................................................................................................... 16 cm.
Weight..................................................................................................................... 22 kg.

Up

CONVERTERS ORT-F1-24 (SINGLE PHASE) & ORT-F3-24 (THREE PHASE)  

CONVERTER CHARACTERISTICS
Transient power....................................................................................................... 60 kW
Starting power (for motors starting)........................................................................ 45 kW
Permanent rms power.............................................................................................. 24 kW
Frequency................................................................................................................ 50 or 60 Hz
Frequency maximum variation................................................................................. 0.1%
Output voltage (rms)................................................................................................ 110, 120, 220, 240 V
Output voltage maximum variation........................................................................... 5%
Reactive energy recovery....................................................................................... > 90%
Performance with resistive loads........................................................................... > 97%

ORT– F1– 24 & ORT– F3– 24 CONVERTERS DIMENSIONS
Length..................................................................................................................... 59 cm.
Width....................................................................................................................... 65 cm.
Height...................................................................................................................... 16.5 cm.
Weight..................................................................................................................... 33 kg.

Up

CONVERTERS ORT-F1-48 (SINGLE PHASE) & ORT-F3-48 (THREE PHASE)  

CONVERTER CHARACTERISTICS
Transient power....................................................................................................... 120 kW
Starting power (for motors starting)........................................................................ 90 kW
Permanent rms power.............................................................................................. 48 kW
Frequency................................................................................................................ 50 or 60 Hz
Frequency maximum variation................................................................................. 0.1%
Output voltage (rms)................................................................................................ 110, 120, 220, 240 V
Output voltage maximum variation........................................................................... 5%
Reactive energy recovery....................................................................................... > 90%
Performance with resistive loads........................................................................... > 97%

ORT– F1– 48 & ORT– F3– 48 CONVERTER DIMENSIONS
Length..................................................................................................................... 80 cm.
Width....................................................................................................................... 65 cm.
Height...................................................................................................................... 16.5 cm.
Weight..................................................................................................................... 49.7 kg.

Up